Every term an architect, engineer, certifier or student meets when working with glass-reinforced concrete, fibre-reinforced polymer and glass-reinforced gypsum, defined in one sentence and explained in one page. 198 entries published, reviewed by ShapeShift Technologies’ engineering team.
Materials25 published
- Aluminium composite panel (ACP): A sandwich of two thin aluminium skins on a polyethylene or mineral core; the material at the centre of the combustible cladding crisis.
- Architectural composites: Fibre-reinforced materials, GRC, FRP and GRG, engineered for building envelopes and interiors.
- Architectural precast: Precast concrete produced for its visible finish rather than structure alone, with controlled colour, texture and form.
- Ballistic panels: FRP or aramid composite panels rated to stop projectiles under standards such as UL 752 and NIJ 0108.
- Carbon fibre reinforced polymer (CFRP): FRP reinforced with carbon fibre for maximum stiffness to weight; used where GFRP deflection limits govern.
- Cladding panels: Any prefabricated exterior sheet, tile or panel fixed to a building’s structure to form the outer skin.
- Composite cladding: Any cladding made from two or more bonded materials, from wood polymer decking boards to aluminium composite panels and fibre-reinforced composites.
- Exterior wall panels: Prefabricated panels forming the outer wall, from load-bearing precast to lightweight rainscreen skins.
- Facade panels: Large-format prefabricated elements that form the visible outer face of a building envelope.
- Fibre cement: A pressed cement, cellulose and silica sheet used for flat cladding; non-combustible but limited to flat or gently curved forms.
- Fibre reinforced concrete: Concrete containing steel, glass, synthetic or natural fibres to control cracking and add toughness.
- Fibre reinforced polymer (FRP): A composite of continuous or chopped fibres, usually glass, in a cured thermoset resin matrix, used for lightweight architectural panels and structural elements.
- Fibreglass: The common name for glass fibre and for GFRP composites made from it.
- FRP facade panels: Exterior cladding panels laminated from glass fibre and thermoset resin, 3 to 8 mm single skin or 10 to 50 mm monocoque, at 5 to 32 kg per square metre.
- FRP versus GRC: Choosing between polymer and cement composites: weight and geometry favour FRP, non-combustibility favours GRC.
- GFRC panels: Factory-made glass fibre reinforced concrete facade or feature panels, typically 12 to 20 mm skins with integral ribs or a steel stud frame.
- GFRC versus precast: A comparison of thin fibre reinforced skins against conventional reinforced precast on weight, cost, lead time and fire.
- GFRG panels: Interior wall and ceiling panels cast from glass fibre reinforced gypsum, paint-ready and non-combustible where tested.
- Glass fibre reinforced concrete (GRC / GFRC): A thin-section cementitious composite of Portland cement, fine sand and alkali resistant glass fibres, formed by spraying or premixing into panels 10 to 20 mm thick.
- Glass fibre reinforced gypsum (GRG / GFRG): A gypsum plaster composite reinforced with glass fibre, cast into thin lightweight interior panels, ceilings and mouldings.
- Glass fibre reinforced polymer (GFRP): FRP whose reinforcement is E glass or ECR glass fibre; the standard composite for architectural FRP facade panels.
- Lightweight cladding: Facade systems under about 50 kg per square metre, reducing structure, crane and transport cost.
- Precast concrete panels: Factory-cast reinforced concrete cladding or structural wall units, typically 100 to 200 mm thick and 250 to 500 kg per square metre.
- Terracotta cladding: Extruded fired clay rainscreen panels or baguettes, non-combustible and heavy at 30 to 60 kg per square metre.
- Ultra high performance concrete (UHPC): A dense, steel or synthetic-fibre-reinforced concrete exceeding 120 MPa compressive strength, used for thin structural facade elements.
Composition20 published
- Alkali resistant glass fibre (AR glass): Glass fibre with 16 percent or more zirconia, resisting the alkaline cement environment; mandatory in GRC.
- Alpha gypsum: High density hemihydrate gypsum used in GFRG for strength and a hard surface.
- Cement matrix: The binder phase of GRC: Portland cement, fine silica sand, water and admixtures.
- Chopped strand mat: Randomly oriented short glass fibres held with a binder, giving isotropic properties in hand lay-up laminates.
- E glass fibre: The standard low alkali borosilicate glass fibre used in FRP laminates; not suitable in cement without coating.
- Epoxy resin: A high-strength thermoset used in structural FRP; more expensive and UV sensitive without coating.
- Fibre volume fraction: The proportion of a composite occupied by fibre; drives stiffness and strength in FRP.
- Foam core: A PVC, PET or PU foam layer between FRP skins that raises stiffness with little weight.
- Gel coat: A pigmented resin surface layer moulded as the outer face of an FRP panel, providing colour, gloss and UV protection.
- Glass fibre: Fine filaments of drawn glass used as reinforcement in composites.
- Low alkali cement: Cements with reduced alkali content used in some GRC to slow fibre degradation.
- Phenolic resin: A thermoset chosen for low flame spread and low smoke; the usual route to better fire classes in FRP.
- Polyester resin: The lowest cost thermoset for GFRP laminates; adequate weathering, moderate chemical resistance.
- Polymer modified GRC: GRC with an acrylic polymer admixture that replaces wet curing and improves surface durability.
- Sandwich panel: Two thin stiff skins bonded to a lightweight core; in FRP, the route to large stiff panels at low weight.
- Silica-free composites: Composites formulated without crystalline silica to eliminate silicosis risk in cutting and finishing.
- Thermoset resin: A polymer that cures irreversibly by cross-linking; polyester, vinyl ester, epoxy and phenolic resins form the matrix of architectural FRP.
- Vinyl ester resin: A thermoset between polyester and epoxy in cost and performance, with better corrosion and fatigue resistance.
- Woven roving: A heavy woven glass fabric used for strength in structural FRP laminates.
- Zirconia content: The zirconium dioxide fraction in AR glass that gives alkali resistance; the GRCA specifies a minimum of 16 percent.
Properties25 published
- Acoustic performance: Sound insulation of the wall build-up; lightweight panels rely on mass in the backing wall.
- Compressive strength: Stress a material carries in crushing; high in all cementitious composites and rarely governs facade design.
- Creep: Slow deformation under sustained load; a design check for FRP under permanent dead load.
- Dead load per square metre: The self-weight of a panel system; it sets crane capacity, substructure size, and slab edge design.
- Deflection limits: Serviceability limits, often span over 180 to 360, that govern FRP panel and rail sizes.
- Density: Mass per unit volume: GRC about 1900 to 2100 kg per cubic metre, GFRP about 1700 to 1900, gypsum composites 1400 to 1700.
- Durability and service life: Expected life without major maintenance; 50 years for GRC and coated FRP under normal exposure.
- Embodied carbon: Greenhouse gas emitted to make, transport, and install a product; expressed as kg CO2e per square metre for facades.
- Environmental product declaration (EPD): A verified document reporting a product’s life cycle impacts to EN 15804; increasingly required for green building credits.
- Flexural strength: Resistance to bending failure; the governing property for thin facade panels under wind load.
- Freeze-thaw resistance: Ability to survive repeated freezing of absorbed water; GRC passes with low water absorption, FRP is immune.
- Green Star and LEED credits: Rating system points available for low carbon, EPD-backed or recycled content materials.
- Impact resistance: Energy absorbed before damage, measured by Charpy or Izod; FRP and GRC both far exceed fibre cement.
- Life cycle assessment: The method behind an EPD: quantifying environmental impact from raw material to end of life.
- Limit of proportionality (LOP): The stress at which a GRC beam first cracks and behaviour stops being linear; used for serviceability design.
- Modulus of rupture (MOR): Peak flexural stress at failure in a bending test; the headline strength figure for GRC, typically 18 to 30 MPa sprayed.
- Moisture movement: Reversible swelling and shrinkage of cementitious composites with humidity; up to 0.1 percent for GRC.
- Recyclability of composites: End-of-life routes for GRC (crushed aggregate) and FRP (mechanical grinding, cement kiln co-processing).
- Strength-to-weight ratio: Strength divided by density; the metric that justifies FRP over GRC and GRC over precast.
- Tensile strength: Maximum stress in direct tension; FRP laminates reach 170 to 270 MPa, GRC 5 to 10 MPa.
- Thermal conductivity: Rate of heat flow through a material; FRP 0.3 to 0.7 and GRC about 0.4 W per metre kelvin versus 205 for aluminium.
- Thermal expansion: Dimensional change with temperature; GRC 10 to 20, FRP 15 to 30 microstrain per degree; governs joint widths.
- Toughness: Energy absorbed to fracture; fibre reinforcement converts brittle cement or resin into a tough composite.
- UV stability: Resistance to chalking and colour change under sunlight; FRP relies on gel coat or coating, GRC is inherently stable.
- Water absorption: Mass gain after immersion; low absorption underpins freeze-thaw and staining resistance.
Testing and standards46 published
- Accredited testing body: A laboratory accredited (NATA, UKAS, IAS) to run fire tests whose reports authorities accept.
- AS 1530.1 combustibility test: The Australian furnace test that decides whether a material is combustible; a pass makes it non-combustible under the NCC.
- AS 1530.3 early fire hazard test: An Australian test giving four indices: ignitability, spread of flame, heat evolved and smoke developed.
- AS 1530.4 fire resistance test: The Australian furnace test for elements of construction, producing a fire resistance level in minutes.
- AS 5113 external wall fire test: Australia’s full-scale facade test, based on BS 8414, giving an EW classification for external wall systems.
- AS 5637.1 group number: The NCC classification of wall and ceiling linings from Group 1 (best) to Group 4, from a room fire test or cone calorimeter prediction.
- AS ISO 9705 room corner test: A full room fire test for linings; the reference method behind group numbers.
- AS/NZS 3837 cone calorimeter: A bench test measuring heat release rate and ignition time under radiant heat; used to predict group numbers.
- ASTM E119 fire resistance: The US furnace test giving hourly fire resistance ratings for walls and floors.
- ASTM E136 non-combustibility: The US furnace test for non-combustible materials referenced by the IBC.
- ASTM E84 flame spread: The US Steiner tunnel test giving a Flame Spread Index and Smoke Developed Index; Class A is FSI 0 to 25.
- BR 135 classification: The BRE performance criteria that turn a BS 8414 test into a pass or fail.
- BS 8414 full-scale facade test: The UK large-scale test of a full external wall system on a 9 metre rig; results are classified under BR 135.
- Building class (NCC): The NCC’s classification of buildings by use, from Class 1 houses to Class 9 public buildings.
- CAN/ULC S114 non-combustibility: Canada’s furnace test for non-combustible materials.
- CAN/ULC S134 full-scale wall test: Canada’s full-scale exterior wall fire test under the National Building Code.
- Cavity barrier: Fire stopping within the rainscreen cavity that limits vertical fire spread.
- Class 0 and Class 1 (BS 476): Legacy UK surface spread of flame classes still referenced in Hong Kong and Singapore codes.
- Combustible cladding: Cladding that fails a combustibility test; the subject of Australian audits and the UK ban after Grenfell.
- Deemed to satisfy: Prescriptive NCC provisions that automatically comply; non-combustible cladding to AS 1530.1 is the DtS route.
- EN 13501-1 classification: The European reaction to fire classes A1 to F with smoke (s1 to s3) and droplet (d0 to d2) sub-classes.
- EN 13501-2 fire resistance: The European classification of fire resistance for elements of construction, such as EI 60.
- EN 13823 single burning item (SBI): A corner test with a gas burner that determines Classes A2 to D in EN 13501-1.
- EN ISO 1182 non-combustibility: The European furnace test for Class A1 and A2; the equivalent of AS 1530.1 and ASTM E136.
- EN ISO 11925-2 small flame test: Ignitability under a small flame; a screening test for Classes B to E.
- Fire engineer: The specialist who designs performance solutions and interprets test results for a specific building.
- Fire rated cladding: A common but imprecise term; cladding is classified by reaction to fire, and only wall assemblies carry a fire resistance rating.
- Fire resistance level (FRL): An Australian rating in minutes for structural adequacy, integrity and insulation, such as 90/90/90; applies to walls, not cladding skins.
- Fire safe facade design: Principles for limiting external fire spread: material class, cavity barriers, spandrel heights and tested assemblies.
- Flame spread index: The ASTM E84 measure of how fast flame travels along a surface.
- Heat release rate: The rate a burning material releases energy, in kilowatts per square metre; the core output of the cone calorimeter.
- IBC Chapter 14 exterior walls: The International Building Code provisions governing exterior wall materials, combustibility and testing.
- IBC fiber reinforced polymer provisions: The IBC section that permits FRP on exterior walls subject to flame spread, NFPA 285 and height limits.
- Ignitability index: The 0 to 20 scale from AS 1530.3 for how readily a surface ignites.
- Limited combustibility: A UK category between non-combustible and combustible, now largely replaced by EN Class A2.
- NCC external wall requirements: NCC 2022 Volume One requires external walls of Type A and B buildings to be non-combustible, with a performance route via AS 5113.
- NFPA 285: The US two-storey fire test for exterior wall assemblies that contain combustible components.
- Non-combustibility: A material that does not burn or release significant heat when tested in a 750-degree furnace; the strictest fire property.
- Non-combustible cladding: Cladding whose material passes a combustibility test; the safest and increasingly mandatory route for external walls.
- Performance solution: An NCC compliance route using verification methods or expert judgement, such as AS 5113 plus fire engineering for combustible cladding.
- Reaction to fire versus fire resistance: Reaction to fire describes how a material burns; fire resistance describes how long an element holds back fire. Cladding is judged on the first.
- Rise in storeys: The NCC count of storeys above ground that, with building class, sets the construction type.
- Smoke developed index: A measure of smoke production in ASTM E84 and AS 1530.3.
- Third party certification: Independent product conformity schemes such as CodeMark (AU), BBA (UK) and ICC-ES (US) that certify tested performance.
- Type A, B and C construction: The NCC’s three fire resistance categories for buildings, set by class and rise in storeys; Type A is the most onerous.
- Wall lining: Internal surface material subject to group number requirements under NCC Specification 7.
Manufacturing23 published
- CNC formwork: Moulds machined by computer-controlled routers from foam, timber or tooling board, enabling complex curved panels.
- Curing: Controlled moisture and temperature after casting; GRC needs seven days of moist cure unless polymer modified.
- Demoulding: Removing the cast panel from its mould, usually after 16 to 24 hours for GRC.
- Digital fabrication: Producing building elements directly from 3D models via CNC and robotics.
- Flex anchor: An L-shaped steel rod bonded to a GRC skin with a pad of GRC, allowing the skin to move relative to the frame.
- Formwork for composites: The mould that gives a cast or laminated panel its shape; the cost driver for complex geometry.
- Gravity anchor: The rigid anchor in a stud frame system that carries panel weight.
- Hand lay-up: Placing glass mat and resin by hand in an open mould; the standard method for bespoke architectural FRP.
- Laminate: The layered structure of fibre and resin that forms an FRP panel skin.
- Lead time: Time from shop drawing approval to delivery; 6 to 16 weeks depending on tooling.
- Lost formwork: Single-use moulds destroyed on demoulding; used for one-off geometry.
- Mock-up: A site or factory assembly of the facade system used for approval and performance testing.
- Monocoque panel: An FRP panel where skin and stiffening form one shell, 10 to 50 mm deep, spanning large areas without a separate frame.
- Mould making: Producing the negative form for casting; silicone, FRP and CNC foam moulds each suit different run lengths.
- Premix GRC: GRC where short fibres are mixed into the slurry before casting; 3 percent fibre, lower strength, suited to smaller elements.
- Prototyping: Full-scale sample panels made to prove finish, geometry and fixing before production.
- Quality control: Batch testing of MOR, density and fibre content against GRCA and ISO 9001 procedures.
- Robotic manufacturing: Use of industrial robots for milling, spraying or trimming composite panels.
- Shop drawings: Fabricator-produced drawings showing every panel, fixing and tolerance for approval before manufacture.
- Sprayed GRC: GRC made by spraying cement slurry and chopped AR glass simultaneously into a mould; 5 percent fibre, highest strength.
- Stay-in-place formwork: Permanent GRC or FRP shells that act as the mould for site-cast concrete and remain as the finish.
- Stud frame GRC: A GRC skin attached to a light steel frame through flexible anchors; the standard system for large facade panels.
- Vacuum infusion: Drawing resin through dry fibre under vacuum for a denser, lighter, more consistent laminate.
Design and detailing32 published
- BIM and facade modelling: 3D building information models used to coordinate, fabricate and document facade panels.
- Cavity and drainage: The space behind the panel that lets water drain and air move; typically 25 to 50 mm.
- Civil infrastructure facades: Composite panels on tunnels, stations, bridges and noise walls where durability and low maintenance govern.
- Curtain wall: A non-load-bearing outer wall hung from the floor slabs, often glazed and unitised.
- Design life: The period a component is designed to last without replacement; 50 years is standard for facades.
- Double curvature: A surface curved in two directions; the geometry that favours moulded composites over pressed metal.
- Finite element analysis: Numerical simulation of stress and deflection used to size FRP and GRC panels.
- Freeform facade: A non-repetitive, sculptural envelope generated from a 3D model.
- Hook-on rail system: Horizontal rails on the substructure that panels hang from via brackets, allowing fast installation.
- Interior cladding: Panels for internal walls and ceilings where group number, not combustibility, is the fire measure.
- Joint design: The detailing of gaps between panels for movement, drainage and appearance.
- MasterSpec: The AIA-owned US master specification system.
- Movement joints: Gaps that absorb thermal, moisture and structural movement; sized from panel length and expansion coefficient.
- NATSPEC: Australia’s national specification system; the clause template most architects use.
- NBS: The UK specification and product platform (NBS Source).
- Open joint: An unsealed gap between rainscreen panels that drains and ventilates the cavity.
- Panel fixing systems: Mechanical methods for attaching panels: concealed undercut anchors, hook-on rails, visible face fixings, flex anchors.
- Panel size and format: The maximum dimensions a material and system allow; FRP to 2.4 by 10 metres, GRC commonly to 3 by 6 metres.
- Parametric design: Model-driven design where geometry responds to rules; produces the unique panels composites are suited to.
- Public art fabrication: Engineering and manufacturing sculptural works from composites for outdoor exposure.
- Rainscreen: A facade with an outer skin, a ventilated drained cavity and an inner weather barrier; the standard system for lightweight panels.
- Rainscreen cladding: Exterior panels installed as the outer skin of a rainscreen system, open or closed jointed.
- Spandrel: The opaque wall zone between windows on successive floors; often specified with a fire resistance requirement.
- Specification: The written performance and prescriptive requirements for a facade package, typically to NATSPEC, NBS or MasterSpec.
- Specifier: The architect or engineer who selects and documents products; the audience for technical content.
- Substructure: The rails, brackets and anchors that carry panels back to the primary structure.
- Thermal bridging: Heat loss through fixings and brackets that penetrate insulation; lightweight panels need fewer and smaller bridges.
- Tolerances: Permitted deviations in structure and panels that fixings must absorb; typically plus or minus 20 mm for structure.
- Undercut anchor: A concealed fixing that expands into a cone-shaped hole drilled in the back of a panel.
- Unitised facade: A curtain wall delivered as factory-assembled storey-height units.
- Ventilated facade: A rainscreen where the cavity is deliberately ventilated to remove moisture and heat.
- Wind load: Pressure and suction on a facade from AS/NZS 1170.2 or local codes; the governing action for thin panels.
Installation12 published
- Crane lift planning: Selecting crane capacity and radius from panel weight; lightweight panels often avoid tower crane time.
- Flashing: Metal or membrane elements that direct water out of the cavity at openings and edges.
- Installation: Site fixing of panels to the substructure by a specialist installer, from setting out to sealing.
- Installer qualifications: Trades licensed and trained for facade work; in Australia, cladding installers face increasing registration requirements.
- Maintenance: Cleaning, inspection and recoating regimes over the design life.
- Recladding: Replacing an existing facade skin; lightweight panels reduce structural upgrades.
- Replacement and remediation: Removing non-compliant combustible cladding and installing a compliant system.
- Sealants: Silicone or polyurethane joint fillers used in closed-joint systems; must be compatible with the panel surface.
- Setting out: Surveying the structure and establishing the grid lines panels are fixed to.
- Site tolerances and packing: Adjusting brackets with shims or slotted holes to absorb structural deviation.
- Transport and handling: Packing, stacking and protecting panels for road or sea freight; drives maximum panel size.
- Weather barrier: The membrane on the inner wall that keeps water out; the rainscreen’s second line of defence.
Finishes15 published
- Acid-etched finish: A light acid wash that removes surface laitance for a fine sandy texture.
- Anti-graffiti coating: A sacrificial or permanent clear coat that lets graffiti be removed without damage.
- Colour consistency: Batch-to-batch uniformity of colour across a facade; a specification and QA issue for GRC.
- Efflorescence: White salt deposits that migrate to the surface of cementitious materials; controlled by mix design and curing.
- Exposed aggregate: A finish where surface cement is removed to reveal decorative aggregate.
- Hydrophobic treatment: Silane or siloxane treatments that repel water and reduce staining.
- Integral colour: Pigment mixed through the material so colour is not a coating.
- Off-form finish: A surface that takes its texture directly from the mould; smooth, board-marked or patterned.
- Oxide pigments: Iron and other metal oxides used to colour cementitious mixes permanently.
- Polished concrete finish: A ground and honed surface, occasionally used on GRC feature elements.
- PVDF coating: A fluoropolymer paint with excellent colour retention, used on FRP and metal facades.
- Sandblasted finish: Abrasive blasting for a matte, uniform texture.
- Surface finish: The visible texture, colour and gloss of a panel; determined by mould, mix and coating.
- Texture and relief: Three-dimensional surface patterns cast from CNC-milled moulds.
- Weathering: Long-term surface change from rain, pollution and sunlight; predictable with the right finish.