Panel Operation & Maintenance Manual

Handover guidance for building owners and facility managers. Choose your panel type to see its inspection and cleaning schedule, repair approach and warranty conditions.

Choose your panel type

Cross-section of layered FRP laminate

FRP · Reinforced thermoset

ShapeShell™-RT

Cross-section of glass fibre reinforced concrete

GRC · Reinforced concrete

ShapeShell™-RC

Inspection

Every year

Qualified engineer

Cleaning

Every year

Record kept

Structural warranty

50 years

From practical completion

Colour warranty

25 years

ΔE not above 5

Maintenance Tasks for ShapeShell™-RT

Engineer inspecting a panel face for cracks and recording findings in a register
Yearly structural inspection

A mechanical, structural or aerospace engineer with more than five years’ composites experience checks the surface and structure for cracks or delamination and keeps an inspection register.

How often: once a year, for the full warranty period

Soft nylon brush and bucket of mild detergent used to wash a panel face
Yearly wash

Warm or cold water with a mild detergent, applied with soft cloths or soft nylon-bristle brushes, then a clean-water rinse. Wire brushes and scouring pads scratch the paint and must not be used.

How often: once a year, with a record kept

Section through a chipped panel showing filler, sanded back and repainted
Superficial paint repair

Chips and deep scratches can usually be filled with a high-quality automotive filler, sanded back and repainted. Contact ShapeShift Technologies first to confirm the procedure.

When: non-structural damage to the paint system

Responsibility. The contractor completes or arranges the required inspections and maintenance, and shares anything affecting structural integrity with ShapeShift Technologies.

Safety and Handling

Safety

  • Wear a body suit, gloves, goggles and a mask when drilling, cutting or sanding.
  • Move panels with care to avoid breakage in transport and installation.
  • Keep panels away from heat sources, open flames and corrosive materials.

Storage and handling

  • Store dry. A dry, well-ventilated area away from direct sunlight and extreme temperatures.
  • Lift, don’t drag. Use suitable lifting equipment and never drop panels.
  • Secure loads. Fasten panels in transit so they cannot shift.
  • Protect the finish. Scratches, dents and cracks affect both performance and appearance.

Structural Repairs

Structural repairs may use laminate patching, resin injection or composite bonding. They must be done by a suitably skilled tradesperson, using the method ShapeShift Technologies confirms as most suitable.

Warranty Conditions

The warranty covers defects in manufacturing and workmanship on panels supplied to the specified and approved finish, and starts on the date of practical completion.

Conditions

  • Panels have not been exposed to temperatures above 70 °C.
  • The maintenance guidelines in this manual have been followed.

Not covered

  • Acts of God beyond the design parameters
  • Direct fire, or temperatures above 70 °C
  • Malicious damage, vandalism, misuse or abuse
  • Negligent cleaning or maintenance
  • Normal wear and tear such as minor scratches and scuffs
  • Impact, abrasion or chemical exposure outside normal conditions

Inspection

6 months → 2 years

6-monthly in year one

Cleaning

Every 6 months

Detergent or pressure wash

Structural warranty

50 years

From practical completion

Colour warranty

Up to 25 years

PVDF colour retention

Maintenance Tasks for ShapeShell™-RC

Engineer inspecting a panel face for cracks and recording findings in a register
Structural inspection

A mechanical, structural or aerospace engineer with more than five years’ GRC experience inspects the structure and keeps an inspection register, in line with industry best practice.

How often: every 6 months in year one, then every 2 years

Soft nylon brush and bucket of mild detergent used to wash a panel face
Regular cleaning

Gently scrub with mild detergent and water, then rinse thoroughly so no residue builds up. Check regularly for dirt or mould and clean promptly to prevent permanent staining.

How often: every 6 months

Pressure washer with wide fan tip held 300 to 450 mm from a GRC panel
Pressure washing

For stubborn stains, about 1,000 to 1,500 psi (roughly 70 to 100 bar) with a wide fan tip, held at least 300 to 450 mm (12 to 18 in) away. Test on a small, hidden area first, then rinse.

When: regular cleaning is not enough

Responsibility. The contractor completes or arranges the required inspections and maintenance, and shares anything affecting structural integrity with ShapeShift Technologies.

Safety and Handling

Safety

  • Wear safety goggles, a dust mask or respirator and sturdy gloves; a hard hat is recommended.
  • Panels can be heavy and awkward. Always use proper lifting techniques.
  • Keep the work area ventilated, tidy and free of trip hazards.
  • Lay mats or tarps to catch dust when installing or cutting.

Storage and handling

  • Store dry. A dry, well-ventilated area.
  • Lift, don’t drag. Use suitable lifting equipment and never drop panels.
  • Cover in transit. Protective covers prevent impact damage, and loads are fastened so they cannot shift.
  • Protect the finish. Cracks and chips affect both performance and appearance.

Structural Repairs

Before any repair, inspect the whole panel surface to find every affected area. Chips or cracks can come from temperature changes, settling of the structure or incorrect installation. Repairs follow ShapeShift Technologies’ instructions and are carried out by personnel ShapeShift Technologies approves.

Warranty Conditions

The warranty covers defects in manufacturing and workmanship on panels supplied to the specified and approved finish, and starts on the date of practical completion.

Conditions

  • Maintenance and routine maintenance have been followed as set out in this manual.
  • Manuals are comprehensive enough for routine maintenance, overhaul and repair by qualified personnel.

Not covered

  • Acts of God beyond the design parameters
  • Direct fire, or temperatures above 70 °C
  • Malicious damage, vandalism, misuse or abuse
  • Negligent cleaning or maintenance

Plan Maintenance From Day One

Our technical team can help with repairs, inspections and warranty questions for ShapeShell™ panels, and with handover documents for your project.

Contact Us

Request Your Sample

Circle of Elders, ShapeShell-RT FRP